Leviton ADVENTUM Central Dry Tube (CDT) B2ca cables provide 2–24 fibers in a compact, gel‑free central dry tube construction for building backbone and riser installations. Cables use bend‑insensitive fibers (single‑mode and multimode), glass yarn strength members, and a halogen‑free flame retardant low‑smoke (HFFR‑LS) outer sheath. CDT B2ca cables meet EN 13501‑6 Euroclass B2ca and are CE marked for CPR. Suitable for internal/external dry duct and cable tray installations where high life‑safety fire performance is required.
Features and Benefits
- 2–24 fiber counts, color‑coded according to TIA‑598‑D.
- Bend‑insensitive fiber as standard — single‑mode, OM1, OM3, OM4, and OM5 versions.
- Dry water‑blocked central tube prohibits ingress of water throughout the tube length.
- Gel‑free central dry tube construction reduces termination time and removes need for solvents.
- Glass yarn armoring provides high tensile strength and rodent protection.
- Halogen‑Free Flame Retardant Low‑Smoke (HFFR‑LS) sheath (black, UV stable as standard).
- CE marked for CPR; Euroclass B2ca meets requirements of Cca, Dca, and Eca.
- Exceeds relevant mechanical and environmental performance defined by IEC 60794‑2‑20.
Technical Specifications
- Type of cable: Central Dry Tube.
- Temperature (Storage): −20 °C to +60 °C.
- Temperature (Installation): −10 °C to +60 °C.
- Temperature (Operating): −20 °C to +60 °C.
Reaction to fire / CPR (EN standards)
- Single cable flame rating: IEC 60332‑1‑2 / EN 60332‑1‑2 — Pass.
- Cable flame rating: EN 50399 — B2ca.
- Smoke emissions: EN 50399 — s1a.
- Flaming droplets/particles: d1.
- Acid gas emission: IEC 60754 / EN 60754 — a1.
- Classification / Euroclass: EN 13501‑6 — B2ca s1a d1 a1.
Mechanical (by fiber count ranges)
- Fiber counts 2–12 / 16–24.
- Max long term load: 450 N.
- Max short term load: 1500 N.
- Min static bend radius: 15 × cable diameter.
- Min dynamic bend radius: 20 × cable diameter.
- Max crush: 1500 N.
- Max impact: 3 impacts @ 2.0 Nm.
- Max torsion: 5 turns (±180°).
- Nom. tube diameter: 3.0 mm (2–12), 3.5 mm (16–24).
- Nom. cable diameter: 6.5 mm (2–12), 7.0 mm (16–24).
- Nom. cable weight: 43 kg/km (2–12), 47 kg/km (16–24).
Optical Performance (as stated)
- Fiber identifiers and references: 108 (G.657.A1), 208 (G.657.A2), OM3/OM4/OM5 per IEC 60793 references.
- Effective/modal bandwidth and attenuation values for OM3/OM4/OM5: OM3 ≥2000 MHz·km @850 nm; OM4/OM5 ≥4700 MHz·km @850 nm; Overfilled launch bandwidth OM3 ≥1500 MHz·km; OM4/OM5 ≥3500 MHz·km; Attenuation @850 nm ≤2.80 dB/km (MM); @1300 nm ≤0.80 dB/km (MM); Single‑mode values: ≤0.38 dB/km @1310 nm; ≤0.25 dB/km @1550 nm (as listed).
Packaging (as stated)
- Reel sizes: 2 km reels 915 × 470 mm flange; 4 km reels 1055 × 515 mm flange (for 2–12 fiber example).
- Gross weight per reel (examples): 2 km — 102 kg; 4 km — 192 kg (PDF lists 102/192 and 111/209 kg depending on table row).
- Reels per pallet: 2 km — 2 reels; 4 km — 1 reel.
Standards & Regulations
- ISO/IEC 11801.
- IEC 60794.
- BS EN 50173‑1.
- IEC 60794‑1‑2.
- EN 13501‑6 (Euroclass B2ca classification).
- CE marked for CPR.
Country of Origin
United Kingdom (UK)
Part Number Configurator Example (as shown)
- Sample part number: GF OM4 CDT 24 LU ‑ B2ca.
- Configurator elements shown in PDF: GF (design); fiber type codes (e.g., 108 = SM G.657.A1; 208 = SM G.657.A2; 062 = OM1; OM3; OM4; OM5); construction = CDT (Central Dry Tube); fiber count (02, 04, 06, 08, 12, 16, 24); outer sheath = LU (HFFR‑LS); Euroclass = B2ca.